Motor Control Solutions for Industrial and Material Handling Equipment

Our name, PE®or Power Electronics® International, Inc.® is synonymous with quality, heavy-duty VFDs and motor control equipment.

MMV123CRH

For use in hoisting/lifting applications without a mechanical load brake and with a conical-rotor hoist motor (requires an encoder for closed-loop control) up to 1 HP at 230V (4.3 A max).

R123H_

A hoist regeneration resistor for use in a 1 HP @ 208-230 VAC hoist (without load brake) closed-loop VFD application. The final letter of the model name is based on the selected duty/class rating.

PE® Incremental Hollow-Shaft Encoders (Tether Type)

PE Encoders are built to work with our closed-loop Multi-Vector™ and MV-Ultra™ drives.

Description

<<< Back to all models in this series

Notice for CRH models:

All MMV-CRH™ (Conical Rotor Hoist) models are specialty VFDs – built from the ground up specifically for hoists with a conical-rotor motor and encoder feedback.

Use the drive listed on this page ONLY IF you have this type of application (contact PE® if you are unsure).

Add one of the resistors listed below to your quote request unless one of the exact models shown is already installed in your application.

Important note regarding Encoders and Pulse Count selection: Many conical-rotor motors used in a hoist application have a BUILT-IN (low ppr count) encoder. In this case, you do not need to select an encoder option below (you should also leave the Encoder Pulse Count option as “Standard”).

However, if your motor DOES NOT have an existing encoder, you will need to supply and mount one on the motor. If you will be adding one of the PE® encoder options shown here, make sure you also select the “P2” model option for the MMV-CRH. Contact PE® if you are unsure.

Select Product Options

Would you like this product installed in an electrical enclosure or control panel?


No load-brake on your hoist, but don’t have a conical rotor hoist motor? View our MV-U™ models instead.


Does your hoist have a separate mechanical load brake (or a self-locking worm gear)? Use the comparable MX-Ultra™ (Open-Loop) model instead.


Add heavy-duty conformal coating to provide extra environmental protection for this unit:

Additional information

Product Type

Variable Frequency Drive

Model Series

Micro-Speed® MV-CRH™

Line Voltage

208-230 VAC

Max HP (kW) @ 208-230VAC

1 HP (0.75 kW)

Max Amps (FLA)

4.3 A

Min Amps (FLA)

2.4 A

Motor Motion Type

Hoisting / Lifting with a CONICAL-ROTOR hoist motor

Motor Control Type

Closed-loop, vector speed control

Speed Controls

Five distinct, adjustable speed inputs (+2 programmable aux inputs); numerous available control modes including infinitely variable. Also includes extra inputs for analog control modes.

Control Voltage (select one)

110V (standard), 24V, Other voltage (specify)

Encoder Pulse Count (select one)

Standard (low ppr count), P2 (high ppr count; >100)

Temperature Rating

Ambient: 14°F to 140°F (-10°C to +60°C) standard. Best in Class! Storage: From -4°F to +158°F (-20°C to +70 °C)

External Regen. Resistor Required?

Yes, regen resistor required for no-load-brake hoisting/lifting applications. Select resistor sizing based on CMAA Duty Rating requirements.

Pair with Regen Resistor Model(s)

R123H(D,E,F,L)

Frame Size

d4, See "Support and Downloads" area for a downloadable dimensional file

Dimensions
Weight 27 lbs
Dimensions 14 × 10.31 × 7.56 in

Product Type

Variable Frequency Drive

Model Series

Micro-Speed® MV-CRH™

Line Voltage

208-230 VAC

Max HP (kW) @ 208-230VAC

1 HP (0.75 kW)

Max Amps (FLA)

4.3 A

Min Amps (FLA)

2.4 A

Motor Motion Type

Hoisting / Lifting with a CONICAL-ROTOR hoist motor

Motor Control Type

Closed-loop, vector speed control

Speed Controls

Five distinct, adjustable speed inputs (+2 programmable aux inputs); numerous available control modes including infinitely variable. Also includes extra inputs for analog control modes.

Control Voltage (select one)

110V (standard), 24V, Other voltage (specify)

Encoder Pulse Count (select one)

Standard (low ppr count), P2 (high ppr count; >100)

Temperature Rating

Ambient: 14°F to 140°F (-10°C to +60°C) standard. Best in Class! Storage: From -4°F to +158°F (-20°C to +70 °C)

External Regen. Resistor Required?

Yes, regen resistor required for no-load-brake hoisting/lifting applications. Select resistor sizing based on CMAA Duty Rating requirements.

Pair with Regen Resistor Model(s)

R123H(D,E,F,L)

Frame Size

d4, See "Support and Downloads" area for a downloadable dimensional file

Dimensions
Weight 27 lbs
Dimensions 14 × 10.31 × 7.56 in

R123H_

Product Type

Hoist / Lifting (without load brake) Regen Resistor

With what model VFD does this resistor work?

MMV123CRH, MMV123H**, MMV123UH, or these same models with a "-XX" suffix.

Class D Resistor Frame Size

R1.1

Class E Resistor Frame Size

Contact PE

Class F Resistor Frame Size

Contact PE

Class L Resistor Frame Size

Contact PE

Dimensions
Weight N/A
Dimensions N/A

PE® Incremental Hollow-Shaft Encoders (Tether Type)

Product Type

Encoders and Encoder Accessories

Encoder Bore Size*

3/8", 1"

Encoder Cable Length (ft)**

No cable, 15, 25, 50, 75, 100, 125, 150, 200, 250, Custom Length

Dimensions
Weight N/A
Dimensions N/A