Motor Control Solutions for Industrial and Material Handling Equipment

Our name, PE®or Power Electronics® International, Inc.® is synonymous with quality, heavy-duty VFDs and motor control equipment.

Micro-Speed® CXR™ (1-20HP Traverse Applications; Standard Brake Relay)

Micro-Speed® CX-R “a2” frame size shown. All CX Series VFDs are rated for up to 60 degrees C!

The versatile and heavy-duty Micro-Speed® CXR™ VFD Series (Standard Brake Relay).

1-5 HP CXR traverse models are also available with a built-in solid-state brake board option (RP models).

Available Models by Voltage (Open to View)

Are you looking for the 25-40 HP CX™ models? Click here for more information.

Model (Click on the name to view the product page)Max HP (kW) @ 208-230VACMax Amps (FLA)Line VoltageExternal Regen. Resistor Required?Select control voltage then check the box OR press Add to Quote
M123CXR1 HP (0.75 kW)4.3 A208-230 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M223CXR2 HP (1.5 kW)8.6 A208-230 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M323CXR3 HP (2.2 kW)10.0 A208-230 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M523CXR5 HP (4 kW)16.5 A208-230 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M723CXR7.5 HP (5.5 kW)24 A208-230 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1023CXR10 HP (7.5 kW)32 A208-230 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1523CXR15 HP (11 kW)48 A208-230 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M2023CXR20 HP (15 kW)56 A208-230 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.

Are you looking for the 25-40 HP CX™ models? Click here for more information.

Model (Click on the name to view the product page)Max HP (kW) @ 460VACMax Amps (FLA)Line VoltageExternal Regen. Resistor Required?Select control voltage then check the box OR press Add to Quote
M146CXR1 HP (0.75 kW)2.4 A460 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M246CXR2 HP (1.5 kW)4.0 A460 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M346CXR3 HP (2.2 kW)5.6 A460 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M546CXR5 HP (4 kW)9.0 A460 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M746CXR7.5 HP (5.5 kW)12.5 A460 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1046CXR10 HP (7.5 kW)16.5 A460 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1546CXR15 HP (11 kW)24 A460 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M2046CXR20 HP (15 kW)29 A460 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.

Are you looking for the 25-40 HP CX™ models? Click here for more information.

Model (Click on the name to view the product page)Max HP (kW) @ 380-415VACMax Amps (FLA)Line VoltageExternal Regen. Resistor Required?Select control voltage then check the box OR press Add to Quote
M138CXR1.47 HP (1.1 kW)2.4 A380-415 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M238CXR2 HP (1.5 kW)4.0 A380-415 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M338CXR3 HP (2.2 kW)5.6 A380-415 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M538CXR5 HP (4 kW)9.0 A380-415 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard)
M738CXR7.5 HP (5.5 kW)12.5 A380-415 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1038CXR10 HP (7.5 kW)16.5 A380-415 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1538CXR15 HP (11 kW)24 A380-415 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M2038CXR20 HP (15 kW)29 A380-415 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.

Are you looking for the 25-40 HP CX™ models? Click here for more information.

Model (Click on the name to view the product page)Max HP (kW) @ 575VACMax Amps (FLA)Line VoltageExternal Regen. Resistor Required?Select control voltage then check the box OR press Add to Quote
M157CXR1 HP (0.75 kW)1.8 A575 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M257CXR2 HP (1.5 kW)3.2 A575 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M357CXR3 HP (2.2 kW)4.7 A575 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M557CXR5 HP (4 kW)7.2 A575 VACNo. Internal dynamic braking regen resistors are built-in (CMAA class D – standard), Contact PE for Class E/F options.
M757CXR7.5 HP (5.5 kW)9.7 A575 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1057CXR10 HP (7.5 kW)13 A575 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M1557CXR15 HP (11 kW)19 A575 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.
M2057CXR20 HP (15 kW)23 A575 VACYes, an external regen resistor is required for traverse/ramp-to-stop applications. Pair this VFD with the appropriate resistor model listed on the product page.

Product Brochure

About the Micro-Speed® CXR™ Models:

Standard CXR™ units are PE-Preset™* for travel motion. The controlled ramp-to-stop deceleration saves you time and money by virtually eliminating brake wear. CXR™ models are perfect for travel applications including (but not limited to) bridge, trolley, monorail, or conveyor applications. Can be used on conical rotor motors. Models are available in sizes ranging from 1-20 HP and with all 3-Phase voltages.

For applications over 20 HP, use the Micro-Speed® MX-Ultra™ series.

If a built-in, two-pole, solid-state brake board could help you save space and wiring in your application, you should also view the Micro-Speed® CXRP™ models (only available on models 5HP and under).

*PE-Preset™: The same high-reliability CX™ models can be used as either an “R” or “RH” model – but they are factory preset for hoist or travel motion allowing for fast and simple installation. Can be changed in the field if necessary.

Service Classes

  • All CMAA Classes A-F
  • AISE TR6 Class 1 to 4
  • ASME HST- 4 H1 to H5
  • HMI H1 to H5

Certification

  • Listed for U.S. and Canada

Upgrade-Path™ Philosophy

  • We engineer all our equipment for quick and easy upgrade or future replacement in the field
  • This philosophy includes equipment sizes, electrical connections, and software settings
  • Past and present methods of programming are subsets of future drive models
  • Years from now, you can be confident that your company, equipment, investment, and technicians won’t be left behind!

Meets FAR Buy American Act (BAA) USC41