Features:
|
 |
Gang-Set™ Smart-Easy™ Instant Programming. |
|
 |
Universal Auto-Detect™ self-setting input. |
|
 |
One control automatically sets to 208-230 VAC or 460 VAC range. |
|
 |
Regeneration resistors are built in. |
|
 |
High Quality faceplate covering electronics for high reliability & safety. |
|
 |
Left & Right limit switch inputs (also programmable functions). |
|
 |
Variable Speed A.C. output |
|
 |
Three phase A.C. input |
|
 |
Thermal overload input trips shown on display |
|
 |
Charge light |
|
 |
Brake contactor control |
|
 |
Hardware is
robust to withstand high vibration of overhead cranes. |
|
 |
And More! |
|
Crane Diagnostics: -Checks control signals -Check pendant station -Checks load brake wear -Check brakes -Stores faults -Trip messages
|
|
Solid
State Brake Contactor
The
SSB is a specially engineered product for use on new Smart-MoveTM drives that will save panel space, wiring and installation time by eliminating the need for an a.c. brake contactor. The small footprint of the Smart-MoveTM is not compromised since the SSB mounts easily within the drive. Easy to attach and easy to wire. The advantage of this option is that no contactor for switching a "high" voltage AC brake is needed on a control panel - single phase only. The unit is available in both a 208-230 VAC version - SSB1 and a Universal Voltage version 208 through 460 VAC - SSB2. The option can be attached at the factory or in the field if required. For use on drives
built after April 1998.

|

|
|
Model
|
VAC
50/60Hz
|
FLA
Full Load Amps
|
HP
208
vac
|
HP
230
vac
|
HP
460
vac
|
HP
575
vac
|
(A)
Regen
Circuitry Included
(all
internal) |
(B)
Regen Resistor
|
(C)
Control Signal
Interface
115vac
|
(D)
Starting Torque
|
|
|
MSM2A23 |
208-230 |
2.4 |
1/2 |
1/2 |
- |
- |
yes |
internal |
built-in |
300% |
|
|
MSM4A23 |
208-230 |
4.3 |
1 |
1 |
- |
- |
yes |
internal |
built-in |
300% |
|
|
MSM5A23 |
208-230 |
5.9 |
1.5 |
1.5 |
- |
- |
yes |
internal |
built-in |
300% |
|
|
MSM7A23 |
208-230 |
7.5 |
2 |
2 |
- |
- |
yes |
internal |
built-in |
300% |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
MSM1A |
460 |
1.2 |
1/4 |
1/4 |
1/2 |
- |
yes |
internal |
built-in |
300% |
|
|
MSM2A |
460 |
2.4 |
1/2 |
1/2 |
1 |
- |
yes |
internal |
built-in |
300% |
|
|
MSM4A |
460 |
4 |
1 |
1 |
2 |
- |
yes |
internal |
built-in |
300% |
|
|
MSM5A |
460 |
5.4 |
1 |
1 |
3 |
- |
yes |
internal |
built-in |
300% |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
MSM1A57 |
575 |
1.5 |
- |
- |
- |
1/2 |
yes |
internal |
built-in |
300% |
|
|
MSM2A57 |
575 |
2.4 |
- |
- |
- |
1 |
yes |
internal |
built-in |
300% |
|
|
MSM3A57 |
575 |
3 |
- |
- |
- |
1.5 |
yes |
internal |
built-in |
300% |
|
|
MSM4A57 |
575 |
4 |
- |
- |
- |
3 |
yes |
internal |
built-in |
300% |
|
|
Selection of Product
Never exceed either the rated
horsepower or the Full Load Amps. Horsepower is approximate using
NEC charts at 1800rpm. Multiple motors can be controlled on the same
motion (use total HP and total amps). Go to the next size if either
is exceeded. ADD "H" to part number for a hoist pre-set control
(load brake style hoist). For safety do not use this
series of product on hoisting without internal Weston
type load brakes. If mechanical holding brake on the hoist is held
open does the load drift down on the hoist? If it does
drift, you definitely do NOT have an internal load brake or it is not
functioning properly. Thoroughly read the manual and follow all
the instructions and safety precautions.
(A) SIZE (SEE
CHART)
The designation [ ] are past sizes. The designation ( )
are approximate future sizes. The size in bold are the
sizes available as of the printing of this brochure. The other
physical sizes are in order of introduction. The reduced size models
may be available without notice. SEE UPGRADE PATH PHILOSOPHY
INFORMATION.
(B)
REGEN CIRCUITRY INCLUDED
Unique to PE is all drives include the regeneration electronic transistor circuitry as standard and does
not need to be
purchased separately. The EXTERNAL regen resistors are
purchased separately.
(C)
REGEN RESISTOR
Horizontal motion control applications for bridge/trolley
monorail etc., will require an external regen resistor bank (sold
separately by PE) unless it is noted as being INTERNAL to the drive.
PE external resistors are designed with special electrical safety
housings. Un-enclosed resistors (such as those used for
reduced voltage starting applications) are dangerous and not safe
for use with any variable speed drive and should never be
used. Unlike generic drives, PE has designed into its drive's
the electronic portion of the regeneration circuitry.
Most Weston Load Brake style hoists do NOT require regen
resistors with PE drives (unique PE feature).
PE discourages the use of external regen resistors on load brake
hoists. Many worm gear hoists, with PE drives, may not require
regen resistors ballasts either.
(D)
CONTROL SIGNAL INTERFACE
PE Drives are designed for overhead crane applications
and they do not require separate interface cards. The control signal
interface is built into the drive (not a separate add-on card or
parts to loosen). 115vac is standard; all other voltages are
available, including 24vac and 48vac or dc.
(E) STARTING
TORQUE
PE drives have the highest starting torque of any drive in
the industry of 300%. Most generic drives are only 180% or less.
|
Bridge Panel - Micro-Speed® Smart-MoveTM
Each standard Bridge Panel
comes with:
|
 |
Micro-Speed® Smart-Move™ crane designed VFD |
|
 |
Quality built to
meet or exceed NEC & UL specifications |
|
 |
30 amp through-door-disconnect |
|
 |
30 amp Mainline contactor - start-stop circuit |
|
 |
Fusing of Branch Circuit and 30 amp mainline |
|
 |
150 VA Control Transformer w/Primary & Secondary Fusing |
|
 |
Easy field wiring to color-coded terminal block on a raised & angled standoff - fits large screwdrivers! |
|
 |
Nema 12/13 Enclosure with special high durability baked gray polyester powder coating. |
|
 |
Three phase A.C. Brake contactor |
|
 |
Thermal overload relay with single phase protection 105°C wiring |
|
 |
All
wiring, terminals, and components computer labeled. |
|
 |
And More! |
|